APC UPS Systems in Dubai

We supply and install APC by Schneider Electric UPS (Uninterruptible Power Supply) systems across Dubai and the UAE — Back-UPS for workstations and networking equipment, Smart-UPS for server rooms, and rack-mount UPS for IT cabinets and communications rooms.

Why UPS Is Non-Negotiable for Dubai IT Infrastructure

Dubai's power grid is reliable by regional standards, but no grid is perfect. Brief voltage sags, micro-outages, and transient spikes occur across all UAE power supplies — and these events, which last milliseconds to seconds, are the most common cause of unexpected server shutdowns, NVR recording gaps, network switch reboots, and corrupted drives in Dubai office environments.

Beyond outages, Dubai's power environment includes significant voltage variation and harmonic distortion from the dense concentration of air conditioning units and industrial equipment sharing building power circuits. APC Smart-UPS's online double-conversion topology completely isolates sensitive IT equipment from all power anomalies — not just outages — by continuously running equipment from a regulated inverter output rather than from raw mains power.

APC by Schneider Electric is the global market leader in UPS systems and the brand installed in virtually every professional server room in Dubai. It is the default specification in rack infrastructure projects, data centre fitouts, and IT closet builds across the region.

APC Products We Supply & Install

APC Back-UPS Pro

Line-interactive UPS for workstations, network switches, NVRs, and small server appliances. Automatic Voltage Regulation (AVR) corrects high and low voltage without switching to battery — extending battery life significantly in Dubai's variable voltage environment. Sizes from 650VA to 1500VA. Desktop tower form factor.

APC Smart-UPS (Tower)

The professional standard for server room UPS. True online double-conversion or line-interactive depending on model — complete isolation of connected equipment from input power. Smart-UPS 750VA to 3000VA in tower form for server closets, pharmaceutical storage rooms, and small comms rooms. Network management card available for SNMP monitoring and automated graceful shutdown.

APC Smart-UPS (Rack-Mount)

1U and 2U rack-mount UPS units for integration into IT racks and comms cabinets. APC Smart-UPS 1000VA to 3000VA RM models — matching the rack form factor of the servers, switches, and patch panels they protect. Rear-facing outlets on many models for clean cable management in 19" racks.

APC Smart-UPS Online (SRT Series)

True online double-conversion UPS for critical workloads requiring zero transfer time on power anomaly. SRT 1000VA to 10000VA for server rooms hosting virtualisation hosts, domain controllers, SQL databases, and NVR systems that cannot tolerate even a 20ms power gap during battery switchover.

APC External Battery Packs

Extended runtime battery packs connecting to compatible Smart-UPS models — increasing battery runtime from the standard 5–10 minutes to 30–60 minutes or longer depending on load. Essential for server rooms in buildings with known generator start time delays or for environments requiring controlled 30-minute shutdown procedures.

APC Network Management Cards

APC AP9641/AP9635 NMCs providing SNMP/web monitoring of UPS status, load, battery health, and input voltage — with automated shutdown of connected hosts via PowerChute software on power failure. Email/SMS alerts on UPS events. Essential for remote monitoring of server room UPS without physical inspection.

How We Size and Install APC UPS for Dubai IT Environments

Load Calculation

UPS selection starts with measuring the actual power draw of every device to be protected — not the nameplate maximums, which are typically 50–60% higher than real-world loads. We use a power meter to measure real load, then select a UPS with sufficient VA capacity at 70–75% of maximum rating (the efficiency sweet spot for APC Smart-UPS). Over-sized UPS running at low load has poor efficiency and accelerated battery degradation. Under-sized UPS triggers overload faults. Getting the sizing right is the foundation of a reliable installation.

Runtime Calculation

Runtime depends on the UPS capacity, the connected load, and the battery count. For a server room, we calculate the runtime required for either: (a) graceful shutdown of all virtual machines and the host before battery exhaustion, or (b) runtime sufficient to bridge the expected generator start time if a generator is present. We provide a runtime calculation for each UPS configuration before installation to confirm it meets the operational requirement.

Rack Integration & Cable Management

Rack-mount UPS installed at the bottom of the rack (weight management — batteries are heavy). Power strips (APC AP7XXXS series) integrated at the rear of the rack with individual outlet metering. Each server and network device connected to the appropriate UPS outlet with the correct C13/C19 IEC cable length. No cable exceeds the rack rear — all excess dressed and Velcro-tied for clean cable management.

Monitoring & Shutdown Configuration

APC Network Management Card installed in the UPS (if not pre-fitted) and configured with SNMP community strings, email alert settings, and web interface credentials. PowerChute Network Shutdown client installed on all connected servers — when the UPS signals low battery, PowerChute triggers a graceful shutdown sequence on all connected hosts in the correct order (application VMs first, domain controller last). This is what prevents data corruption and dirty filesystem states before battery exhaustion.

Battery Replacement — Don't Ignore It

APC UPS batteries typically require replacement every 3–5 years depending on operating temperature. In Dubai's climate, where server rooms regularly reach 25–30°C or higher, battery degradation is accelerated. A UPS with a degraded battery works correctly on mains power but fails to provide the expected runtime on power failure — you discover this at the worst possible moment.

We recommend annual UPS battery health checks and proactive replacement at 3 years in Dubai environments. APC original replacement batteries (RBCs) are available locally and are straightforward to replace without tools. We can include UPS battery maintenance in your IT support contract.

APC UPS for Every Dubai IT Application

Server Rooms & IT Closets

Rack-mount APC Smart-UPS protecting switches, servers, and patch panels. Network management card for SNMP monitoring. PowerChute server shutdown automation. Runtime calibrated for graceful shutdown before battery exhaustion.

CCTV & NVR Systems

APC Back-UPS behind NVR recorders and PoE switches — prevents NVR crash and recording gaps during power events. Maintains CCTV recording through brief outages without operator intervention. Critical for DHA clinic and retail CCTV compliance.

Office Workstations

APC Back-UPS 650VA–1000VA per workstation cluster — protects against data loss from unexpected shutdowns. AVR corrects voltage irregularities that accelerate power supply degradation in desktop PCs.

Access Control Panels

Small APC Back-UPS or dedicated 12V UPS modules behind ZKTeco and Hikvision access control panels — ensures doors remain in correct (fail-secure or fail-safe) state during power outages rather than defaulting to unintended states.

Networking Equipment (ISP Room)

APC Smart-UPS protecting the building's ISP termination point, main distribution switch, and firewall — ensuring network connectivity is maintained during power events even if individual floors experience outage.

Pharmacies & Medical Equipment

APC UPS for medication dispensing systems, electronic point-of-sale with prescription records, and any medical device requiring clean conditioned power. Double-conversion SRT series for sensitive medical electronics.

Supply & Install APC UPS for Your Dubai IT Room

Tell us what equipment needs protection, whether it's rack or tower, and your runtime requirements. We'll select the right APC UPS and provide a full supply and installation quote within 24 hours.

Request an APC UPS Quote